PROVA-2000/2003 Clamp Meter
|
|
- DC/AC 2000A
- Cable f 55mm, Bus Bar 72mm(D) x 22mm(W)
- True RMS (2000)
- Average Sensing (2003)
- DCA One Touch Zero
- Auto Range A, V, W
- Continuity
- Max/Min/Hold
- Relative Measurement
|
DC Current (Autorange & Manual) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400A
|
0.1A
|
+/- 1.5% +/- 3dgts
|
3000A
|
2500A
|
1A
|
+/- 1.5% +/- 3dgts
|
3000A
|
|
AC Voltage (Autorange & Manual, True RMS for PROVA 2000, Input Impedance 5M W for all ranges) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
4V
|
0.001V
|
+/- 1.5% +/- 5dgts
|
800VAC
|
40V
|
0.01V
|
+/- 1.5% +/- 5dgts
|
800VAC
|
400V
|
0.1V
|
+/- 1.5% +/- 5dgts
|
800VAC
|
600V
|
1V
|
+/- 1.5% +/- 5dgts
|
800VAC
|
|
Resistance ( Ω ) (Autorange & Manual, Open Circuit Voltage<=0.5V) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
400 Ω
|
0.1 Ω
|
+/- 1.5% +/- 3dgts
|
600VAC
|
4K Ω
|
1 Ω
|
+/- 1.5% +/- 3dgts
|
600VAC
|
40K Ω
|
10 Ω
|
+/- 1.5% +/- 3dgts
|
600VAC
|
400K Ω
|
100 Ω
|
+/- 1.5% +/- 3dgts
|
600VAC
|
4M Ω
|
1K Ω
|
+/- 1.5% +/- 3dgts
|
600VAC
|
40M Ω
|
10K Ω
|
+/- 1.5% +/- 3dgts
|
600VAC
|
|
Range
|
Continuity Beeper
|
Open Circuit Voltage
|
Overload Protection
|
400 Ω
|
<=40 Ω (approx.)
|
<=0.5V
|
600VAC
|
|
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload Protection
|
100-1000KHz
|
0.01-100Hz
|
+/- 0.5% +/- 2dgts
|
10mV/0.1V/1V
|
AC 600V
|
|
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
3V
|
0.001V
|
+/- 2.5% +/- 5dgts
|
600VAC
|
|
Current Analog Output (Overload Protection 600V) |
Range
|
Output
|
Accuracy
|
Overload Protection
|
400A
|
1mV/A
|
+/- 2.5% +/- 0.5A
|
600VAC
|
2500A
|
1mV/A
|
+/- 2.5% +/- 5A
|
600VAC
|
|
DC Voltage (Autorange & Manual, Overload Protection 800VAC for all ranges)
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
400mV
|
0.1mV
|
+/- 1.0% +/- 3 dgts
|
10M W
|
4V
|
0.001V
|
+/- 1.0% +/- 3 dgts
|
5M W
|
40V
|
0.01V
|
+/- 1.0% +/- 3 dgts
|
5M W
|
400V
|
0.1V
|
+/- 1.0% +/- 3 dgts
|
5M W
|
600V
|
1V
|
+/- 1.0% +/- 3 dgts
|
5M W
|
|
AC Current (Autorange & Manual, True RMS for PROVA 2000) |
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
50/60Hz
|
40-400Hz
|
400A
|
0.1A
|
+/- 1.5% +/- 5dgts
|
+/- 2.0% +/- 5dgts
|
3000A
|
2100A(0-1000)
|
1A
|
+/- 2.0% +/- 5dgts
|
+/- 2.5% +/- 5dgts
|
3000A
|
2100A(1000-2100)
|
1A
|
+/- 2.5% +/- 5dgts
|
+/- 3.0% +/- 5dgts
|
3000A
|
|
Jaw Opening |
Cable f 55mm Bus Bar 65mm(D)x24mm(W) |
Power Source |
One 006P 9V or IEC 6F22 or NEDA 1604 Battery |
Operating Temperature |
0 ℃ to 40 ℃ (32 ℉ to 104 ℉ ) |
Operating Humidity |
Less than 80% RH |
Dimensions |
271mm(L)x112mm(W)x46mm(H) 10.7"(L)x4.4"(W)x1.8"(H) |
Weight |
647g/22.8 oz (Battery included) |
|