Tes-5200, Particle mass Counter
* Particle mass & particle counter in a single handheld unit.*Six mass ranges and eight particle sizes.
*User K-factors setting for special particulate with different densities.
*Integrated temperature / humidity sensor (no need for external add-on).
*Flow rate 2.83 L / minute (0.1 CF / minute).
*Rechargeable battery provides up to 4 hours of continuous operation (charge time 2 hours).
*Buffer function allows storing and redisplay of up to 500 measurement data sets.
*SD storage device.
*Optical system:Sideway light-scattering method
*Light source:Laser diode
*Laser product class:Class 1, IEC 60825-1 / EN 60825-1
*Mass:
*Mass concentration ranges:PM1, PM2.5, PM4, PM7, PM10, and TSP
*Concentration range:0 to 1000 mg/m3
*Sample time:1 minute (2.83 L / min)
*Particle:Particle size (8 channels):0.5μm、0.7μm、1.0μm、2.5μm、4.0μm、5.0μm、7.0μm、10μm
*Counting Efficiency:100% for particles > 0.45mm (per JIS B9921:1997)
*Sample flow rate:2.83 L / min
*Maximum particle concentration:105,900 particles / L (coincidence loss max. 5%) Measurement time:6 s. (0.01CF), 21 s. (1L), 1 min. (0.1 CF, 2.83L), 3 min. 32 s (10L), 10 min. (1 CF, 28.3L), any length (MANUAL), any length (1 s. to 59 min. 59 s.) Relative Humidity:±7%, 20% to 90% non-condensing Temperature:±3°C, 10°C to 40°C (50°F to 104°F)
*Buffer function:Store and recall values for up to 500 measurements
*PC interface:USB interface
*Temperature / humiditymeasurable range:10°C to 40°C, 20% to 90%RH (approximate)
*Power requirements:Built-in battery or AC adapter
*Supplied Accessories:Users manual, AC adapter, USB connector, Carrying case.
Optical system | Triple 4 digit LCD display |
Light source | Laser diode |
Laser product class | Class 1, IEC 60825-1 / EN 60825-1 |
Sample flow rate | 2.83L / min |
Particle size (6 channels) | 0.3μm, 0.5μm, 1.0μm, 2.0μm, 5.0μm, 10μm |
Counting Efficiency | 50% @0.3μm; 100% for particles >0.45μm (per JIS B9921:1997) |
Relative Humidity | ±7%, 20% to 90% non-condensing |
Temperature | ±3℃, 10℃ to 40℃ (50℉ to 104℉) |
Maximum particle concentration | 70,000 particles / L (coincidence loss max. 5%) |
Measurement time | 6s.(0.01CF), 21s.(1L), 1min.(0.1CF,2.83L) 3min.32s.(10L), 10min.(1CF,28.3L) any length (MANUAL), any length (1s. to 59min.59s) |
Buffer function | Store and recall values for up to 500 measurements |
PC interface | USB interface |
Tempersture / humidity measurable range | 10℃ to 40℃, 20%RH to 90%RH (approximate) |
Power requirements | Built-in battery or AC adapter |
Battery | Rechargeable nickel metal hydride (Ni-MH) battery. charged from supplied AC adapter when power is ON (charge time 2 hours). |
AC adapter | Input voltage: 100 to 240V AC, 50/60Hz |
Dimensions and weight | 212(L) x 120(W) x 60(H)mm / Approx. 930g |
Supplied Accessories | Users manual, AC adapter, USB connector, Carrying case. |