TES-3050 TRMS AC/DC Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
- 3-3/4 Digital LCD with bar-graph
- Auto-ranging off / Data Hold / Peak Hold / MAX/MIN mode
- Zero Adjustment/Relative Reading
|
A: General Measurement
|
Range |
DC-400mV/4V/40V/400V/600V AC-4V/40V/400V/750V |
Accuracy |
DC - 0.75% rdg + 2dgts AC - 1.2% rdg + 5dgts |
Resolution |
0.1mV (DC); 0.001V (AC) |
Input Impendence |
11M Ω |
Overload Protection |
DC 1100V & AC 800V |
|
Range |
400/1000A |
Accuracy |
2% rdg + 10dgts |
Resolution |
0.1A |
Overload Protection |
1100A |
|
Sound Level |
below 40 W |
Max Open Circuit Voltage |
0.5V |
Diode Resolution |
0.001V |
Accuracy |
1% rdg + 2dgts |
|
Range |
400 Ω /4KΩ /40KΩ /400KΩ /4M Ω /40M Ω |
Accuracy |
1% rdg +3dgts |
Resolution |
0.1Ω |
Accuracy |
1% rdg + 2dgts |
Overload Protection |
600Vrms (Also for continuity & Diode) |
Max open Circurit Voltage |
0.5V |
|
Range |
100Hz/1KHz/10KHz/100KHz/800KHz |
Accuracy |
0.1% rdg + 2dgts |
Resolution |
0.01Hz |
Max Input Sensitivity |
100mV |
Overload Protection |
600Vrms |
|
B. Peak Hold Measurement
|
Range |
400/1000A |
Accuracy |
2.5% rdg + 10dgts |
Resolution |
0.1A |
Overload Protection |
1100A |
|
Range |
4V/40V/400V/750V |
Accuracy |
2.5% rdg + 10 dgts |
Resolution |
0.001V |
Input Impedance |
11M Ω |
Overload Protection |
DC 1100V & AC 800V |
Numerical Display |
3 3/4 digit liquid crystal display (LCD) maximum reading 3999 |
Sampling Rate |
20 times/sec (Bargraph ) 2 times/sec (Digital Display) |
Power Source |
one 006p 9V or IEC 6F22 or NEDA 1604 Battery |
Dimensions |
239(L) x 66(W) x 34(H) mm |
Weight |
Approx. 365g |
|