TES- 3079 HVAC Trms Clamp Meter (1000A)


 

HVAC Application
  • Check current draw in motors and compressors.
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
  • Confirm power sources
  • Analyze temperature and power data with the aid of the time stamp.
  • Insulation test up to 100M.
Electrical Application
  • Check for energized circuits.
  • Balance loads.
  • Evaluate electrical contacts.
  • Capture motor in-rush current readings.
  • Determine peak power demand periods.
  • Verify line voltage stability.
  • Monitor motors and other loads for excess heat.
  • Check motor run/start capacitor values.

 

AC Current (50Hz to 400Hz) : Trms
Range
Resolution
Accuracy
Sensitivity
Overload Protection
99.99A
10mA
±2% ±20dgts (50,60Hz)
±4% ±20dgts (40~400Hz)
0.10A
1000A
999.99A
100mA
1.0A
AC Voltage (50Hz to 400Hz) : Trms
Range
Resolution
Accuracy
Sensitivity
Overload Protection
999.9mV
0.1mV
±1% ±20dgts (50,60Hz)
±1% ±20dgts (50,60Hz)
2.0mV
600V
9.999V
1mV
±1% ±20dgts (50,60Hz)
±2% ±20dgts (40~400Hz)
0.020V
99.99V
10mV
0.20V
600.0V
100mV
2V
Input impedance : 3MΩ
Resistance (Continuity<40Ω on the 999.9Ω range)
Range
Resolution
Accuracy
Overload Protection
999.9Ω
100mΩ
1.0% ±10dgts
600V
9.999Ω
99.99Ω
10Ω
999.9Ω
100Ω
Range
Resolution
Accuracy
Overload Protection
9.999MΩ
1KΩ
5% ±10dgts
600V
99.99MΩ
10KΩ
Diode (Continuity<40mV)
Range
Resolution
Accuracy
Overload Protection
2.000V
1mV
±2% ±1dgt
600V
TRUE Power : (PF>0.7 or θ<45 ° )
Range
Resolution
Accuracy
Overload Protection
60.00KW (<100A)
10W
±5%rdg ±20dgts
(50, 60Hz)
600VAC/
1000AAC
600.0KW (>100A)
100W
Frequency
Range
Resolution
Accuracy
Sensitivity
40Hz / 1KHz
0.1Hz
±0.5%rdg ±2dgts
ACV>0.2V, ACA>6A
μA Trms : (AC+DC) (Burden Voltage : 5mV/μA)
Range
Resolution
Accuracy
Sensitivity
Overload Protection
99.99μA
10nA
±1% ±20dgts
0.20μA
600V
999.9μA
100nA
2.0μA
DC Voltage
Range
Resolution
Accuracy
Sensitivity
Overload Protection
999.9mV
0.1mV
±1.0% ±20dgts
2.0mV
600V
9.999V
1mV
0.020V
99.99V
10mV
0.20V
600.0V
100mV
2V
Input impedance : 3MΩ
Capacitance
Range
Resolution
Accuracy
Overload Protection
10.000μF
1nF
1.5% ±5dgts
600V
100.00μF
10nF
1000.0μF
100nF
7000μF
1μF
2.5% ±15dgts
Temperature (K-Type thermocouple)
Range
Resolution
Accuracy
Overload Protection
-50℃ to 900℃
0.1℃
1% ±1℃
30V AC or 60V DC
-58℃ to 1000℉
0.1℉
1% ±2℉
Phase Angle : (50Hz, 60Hz)
Range
Resolution
Accuracy
Sensitivity
50Hz / 60Hz
0.1°
±3.0°
ACV>100V, ACA>10A
Apparent Power
Range
Resolution
Accuracy

Overload Protection

60.00KVA (<100A)
10VA
±2.5%rdg ±20dgts
600VAC/1000AAC

Water Analysis