TES-3900/TES-3901

Clamp Meter/Trms Clamp Meter

Product Features
  • Variable-frequency drives (VFD) V & Hz measurement.
  • LoZ voltage measurement to drain ghost voltages.
  • Check 3 phase sequence.
  • Motor Inrush current measurement.
  • True RMS reading on AC and DC+AC mode. (3901)
  • uA measurement for HVAC flame sensors. (3901)
  • mV measurement range to interface with other accessories. (3901)
  • Crest Factor & Harmonic ratio measurement. (3901)
  • Data hold, Auto hold & Peak hold mode.
  • Max/Min record mode.
  • Data memory & read function.

Model

3900

3901

AC current

Range

99.99A / 999.9A

99.99A / 999.9A

Accuracy

±2%±20dgts (50, 60Hz)

±4%±20dgts (40 to 400Hz)

±2%±20dgts (50, 60Hz)

±4%±20dgts (40 to 400Hz)

AC voltage

Range

999.9V

999.9mV to 999.9V

Accuracy

±1%±10dgts (50, 60Hz)

±2%±10dgts (40 to 400Hz)

±1%±10dgts (50, 60Hz)

±2%±10dgts (40 to 400Hz)

DC voltage

Range

99.99V / 999.9V

999.9mV to 999.9V

Accuracy

±1%±10dgts

±1%±10dgts

Resistance

Range

999.9Ω/99.99KΩ

999.9Ω to 999.9KΩ

Accuracy

±1%±10dgts

±1%±10dgts

Diode

Range

3.000V

3.000V

Accuracy

±2%±10dgt

±2%±10dgt

Frequency

Range

0.5Hz to 800.0Hz

0.5Hz to 800.0Hz

Accuracy

±0.5%rdg±2dgts

±0.5%rdg±2dgts

mA (AC+DC)

Range

99.99mA/999.9mA

Accuracy

±1%±20dgts

Continuity

≤40Ω±30Ω

≤40Ω±30Ω

3f Phase sequence indication

yes

yes

ACA Inrush current

yes

yes

Data hold

yes

yes

Auto hold

yes

yes

Peak hold

yes

yes

Max/Min

yes

yes

Memory/Read

yes

yes

Accessories

Instruction Manual, Battery, Carrying case & Test Lead

Size

HxWxD (mm)

236x80x39

236x80x39

Max wire diameter

30mm

30mm

Weight

326g

326g

Category

CAT III 1000V , CAT IV 600V

CAT III 1000V , CAT IV 600V