PROVA-5601/5637 Clamp-on Ground Resistance Tester
|
|
- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- Jaw Diameter Φ 23 mm (5601)
- Jaw Diameter Φ 35 mm(5637)
- 0.025 – 1500 Ohm
|
- 0.2mA– 30A(5601)0.2mA– 35A(5637),True RMS
- 116 Sets of Memory(5601,5637)
- Programmable Hi and Lo Alarm(5601,5637)
- Programmable Data Logging (5601,5637)
|
|
- Telecommunication
- Cable TV system
- Electrical Power Plant
|
- Cellular Phone System
- Factory and Facility
- Gas Station Tank
|
Ground Resistance (Auto range) |
Range
|
Resolution
|
Accuracy of Reading 1,2
|
0.025 - 0.250 Ω
|
0.002 Ω
|
± 1.5% ± 0.05 Ω
|
0.250 - 1.000 Ω
|
0.02 Ω
|
± 1.5% ± 0.05 Ω
|
1.001 - 9.999 Ω
|
0.02 Ω
|
± 1.5% ± 0.1 Ω
|
10.00 - 50.00 Ω
|
0.04 Ω
|
± 2.0% ± 0.3 Ω
|
50.01 - 99.99 Ω
|
0.04 Ω
|
± 2.0% ± 0.5 Ω
|
100.0 - 200.0 Ω
|
0.4 Ω
|
± 3.0% ± 1.0 Ω
|
200.1 - 400.0 Ω
|
2 Ω
|
± 5.0% ± 5 Ω
|
400.1 - 600.0 Ω
|
5 Ω
|
± 10% ± 10 Ω
|
600.1 - 1500 Ω
|
20 Ω
|
± 20%
|
1 Loop resistance noninductive, external field < 200 A/m, external electrical field < 1 V/m, conductor centered.
2 Resistance Measurement Frequency: 1.667KHz,3.333KHz(optional)
|
|
Ground/Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.5) |
Range
|
Resolution
|
Accuracy of Reading
|
0.200 - 1.000 mA
|
0.001 mA
|
± 2.0% ± 0.05 mA
|
1.00 - 10.00 mA
|
0.01 mA
|
± 2.0% ± 0.03 mA
|
10.0 - 100.0 mA
|
0.1 mA
|
± 2.0% ± 0.3 mA
|
100 - 1000 mA
|
1 mA
|
± 2.0% ± 3 mA
|
0.20 - 4.00 A
|
0.001A
|
± 2.0% ± 0.03A
|
4.00 - 30.00 A(5601)
|
0.01A
|
± 3.0% ± 0.03A
|
4.00 - 35.00 A(5637)
|
0.01A
|
± 3.0% ± 0.03A
|
|
Accuracy of Resistance Calibration Plate |
±0.5% |
Data Logging Capacity |
116 records |
Data Logging Interval |
1 to 255 seconds |
Conductor Size |
35mm /1.38”(5637), 23mm /0.90”(5600,5601) |
Jaw Opening |
38mm /1.49”(5637), 27mm /1.06”(5600,5601) |
Battery Type |
9V IEC 6 LR61 (Alkaline) |
Display Type |
4 digits 9999 counts LCD |
Overload Indication |
OL |
Battery Life |
3000 measurements |
Low Battery Indication |
|
Range Selection |
Auto |
Power Consumption |
40mA |
Sampling Time |
0.5 seconds |
Operating Temperature |
0 ℃ to 50 ℃ (14 ℉ to 122 ℉ ) Operating Humidity: Less than 85% RH |
Storage Temperature |
-20 ℃ to 60 ℃ (-4 ℉ to 122 ℉ ) Storage Humidity: Less than 75% RH |
Dimension( 5637 |
276mm (L) x 100mm(W) x 47mm(H),10.8" (L) x 3.9"(W) x 1.9"(H) |
Dimension( 5600,5601 ) |
257mm (L) x 100mm(W) x 47mm(H),10.1" (L) x 3.9"(W) x 1.9"(H) |
Weight( 5637) |
750g/1.65lbs |
Weight( 5600,5601) |
640g/1.41lbs |
Accessories |
- Resistance Calibration Plate x 1
- Battery 9V (Installed) x 1
- Carrying Box x 1
- Users Manual x 1
|
|