AFLEX-3003 Flexible VA Harmonics Tester
AFLEX -3005 Flexible Power Quality Tester
|
|
Power Analysis (3005)
- W, KW, H.P.
- VA ,KVA, VAR, KVAR
- PF, Phase Angle( Φ )
- Energy (WH, KWH)
- Dual displays (W+PF, VA+KVAR)
- Balanced 3 Φ Power Quality and Sequence
|
Harmonics Analysis
- True RMS (V and A)
- 3000 A
- Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
- Analysis of % THD-F and C.F.
- Fast Peak Function (33μs and 39μs)
- Programmable PT (1 to 250 )ratios
- Auto - Power - Off : 30 Minutes
|
Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm
AC Watt (50 or 65 Hz, PF 0.5 to 1, CT=1) AFLEX-3005 only
|
Range
|
Resolution
|
Accuray of reading
|
100.0 - 999.9 W
|
0.1 W
|
2% of range
|
1.000 - 9.999 KW
|
0.001 KW
|
2% of range
|
10.00 - 99.99 KW
|
0.01 KW
|
2% of range
|
100.0 - 999.9 KW
|
0.1 KW
|
2% of range
|
1000 - 9999 KW
|
1 KW
|
2% of range
|
|
AC Voltage(50 or 65 Hz, ,Auto Range, True RMS)
|
Range
|
Resolution
|
Accuracy of reading
|
4.0 V - 600 V
|
0.1 V
|
±0.5% ± 5dgts
|
|
Harmonics of AC Current in % and Magnitude(1 to 50th order)
|
Range
|
Resolution
|
Accuracy in %
|
Accuracy of Magnitude
|
1-20th
|
0.1%
|
±2%
|
±2% of reading ±0.4A
|
21st-50th
|
0.1%
|
±4% of reading ±2.0%
|
±4% of reading ± 0.4V
|
|
AC Current(50 or 65 Hz ,Auto Range, True RMS)
|
Range
|
Resolution
|
Accuracy of reading
|
0 - 300.0 A
|
0.1 A
|
1% of range
|
300.0 - 999.9 A
|
0.1 A
|
1% of range
|
1000 - 3000 A
|
1 A
|
1% of range
|
|
Harmonics of AC Voltage in % and Magnitude(1 to 50th order)
|
Range
|
Resolution
|
Accuracy in %
|
Accuracy of Magnitude
|
1-20th
|
0.1%
|
±2%
|
±2% ±0.5V
|
21st-50th
|
0.1%
|
±4% of reading ±2.0%
|
±4% of reading ± 0.5V
|
|
Total Harmonics Distortion(%THD-F,1 to 50th order)
|
Range
|
Resolution
|
Accuracy of reading
|
0.0-20%
|
0.1%
|
±2%
|
20-100%
|
0.1%
|
±6% of reading ±1%
|
100-999.9%
|
0.1%
|