TES-2900 True RMS Multimeter with Datalogger


 

Applications:
You can get an accurate ground resistance measurement in the presence of offset voltage.
Features
Smart ohm for ground resistance measurement.
Variable – frequency drive (VFD) V & Hz measurement.
Lo – Z voltage measurement to drain ghost voltages.
Check 3 phase sequence.
Data hold, Auto hold & Peak hold mode.
Max/Min/Avg record mode.
Relative value display.
Frequecy count. (Auto-Range)
Temperature type K, J measurement.
Capacitance measurement.
Data memory & read function.

 


AC Voltage
AC conversions are ac-coupled and valid from 3 % to 100 % of range.

Range

Resolution

Accuracy

45 – 65Hz

15 – 200Hz

200 – 440Hz

440Hz -1kHz

1 – 5kHz

5 – 20kHz

999.9 mV

0.1 mV

±(0.7%+4)

±(1.0 % + 4)

±(2%+4)

±(2%+20)

    (1)

9.999 V

0.001 V

99.99 V

0.01 V

±(0.7%+2)

±(2%+4)

    (2)

Unspecified

999.9 V

0.1 V

Unspecified

VFD

±(1.0%+4)

+1.0%+4

-6.0%-4  (3)

Unspecified

Unspecified

Unspecified

(1) Below 10 % of range, add 12 counts.

(2) Frequency range: 1 to 2.5 kHz

(3) Specification increases from -1 % to -6 % at 440 Hz when filter is used.

DC Voltage, Conductance, and Resistance

Function

Range

Resolution

Accuracy

mV dc

999.9 mV

0.1mV

±(0.1 % + 1)

V dc

9.999 V

0.001 V

±(0.05 % + 1)

99.99 V

0.01 V

999.9 V

0.1 V

Ω

999.9 Ω

0.1 Ω

±(0.2 % + 2)   (2)

9.999 kΩ

0.001 kΩ

±(0.2 % + 1)

99.99 kΩ

0.01 kΩ

999.9 kΩ

0.1 kΩ

9.999 MΩ

0.001 MΩ

50.00 MΩ

0.01 MΩ

±(1.0 % + 1)   (1)

nS

99.99 nS

0.01 nS

±(1.0 % + 10)   (1,2)

(1) Add 0.5 % of reading when measuring above 30 MΩ in the 50 MΩ range, and 20 counts below 33 nS in the 100 nS range.

(2) When using the rel function to compensate for offsets.

Temperature

Thermocouple Type

Range

Accuracy

K

-40 to 500°C 
 (-40 to 932°F )

±0.3%±1°C 
(2°F )

J

-40 to 500°C 
 (-40 to 932°F )

(1) Does not include error of the thermocouple probe.

(2) Accuracy specification assumes ambient temperature stable to ± 1 °C
     For ambient temperature changes of ± 5 °C, rated accuracy applies after 2 hour.

AC Current

Function

Range

Resolution

Burden Voltage

Accuracy

μA ac

999.9μA

0.1μA

100μV/μA

±(1.0 % + 2)

9999μA

1μA

100μV/μA

mA ac

99.99 mA

0.01 mA

1.8 mV/mA

400.0 mA

0.1 mA

1.8 mV/mA

A ac

9.999 A

1 mA

0.03 V/A

AC conversions are ac coupled, true rms responding, and valid from 3 % to 100 % of range, except 400 mA range.

(5 % to 100 % of range) and 10 A range (15 % to 100 % or range).

DC Current

Function

Range

Resolution

Burden Voltage

Accuracy

μA dc

999.9μA

0.1μA

100μV/μA

±(0.2 % + 4)

9999μA

1μA

100μV/μA

±(0.2 % + 2)

mA dc

99.99 mA

0.01 mA

1.8 mV/mA

±(0.2 % + 4)

400.0 mA

0.1 mA

1.8 mV/mA

±(0.2 % + 2)

A dc

9.999 A

1 mA

0.03 V/A

±(0.2 % + 2)

Capacitance

Range

Resolution

Accuracy

10.00 nF

0.01 nF

±(1.0 % + 2) (1)

100.0 nF

0.1 nF

1.000 μF

0.001 μF

±(1.0 % + 2)

10.00 μF

0.01 μF

100.0 μF

0.1 μF

9999 μF

1 μF

(1) With a film capacitor or better, using the rel mode to zero residual.

Diode

Range

Resolution

Accuracy

9.999 V

0.001 V

±(1.0 % + 1)

3f Phase sequence indication :

Range

Frequency Response

Overload Protection

80V to 480V

50Hz / 60Hz

1000V

Frequency

Range

Resolution

Accuracy

99.99 Hz

0.01 Hz

±(0.005 % + 1)     (1)

999.9 Hz

0.1 Hz

9.999 kHz

0.001 kHz

99.99 kHz

0.01 kHz

(1) From 0.5 Hz to 100 kHz and for pulse widths >2μs.

Frequency Counter Sensitivity and Trigger Levels

Input Range

Minimum Sensitivity (RMS Sine Wave)

Approximate Trigger Level

(DC Voltage Function)

5 Hz – 10 kHz

0.5 Hz – 100 kHz

999.9 mV dc

70 mV (to 400 Hz)

70 mV (to 400 Hz)

40 mV

999.9 mV ac

150 mV

150 mV

-

9.999 V

0.3 V

0.7 V

1.7 V

99.99 V

3 V

7 V (≤140 kHz)

4 V

999.9 V

30 V

70 V (≤14.0 kHz)

40 V

Duty Cycle (Vdc and mVdc)

Range

Accuracy

0.0 % to 99.9 %     (1)

Within ± (0.2 % per kHz + 0.1 %) for rise times < 1 μs.

(1) 0.5 Hz to 100 kHz, pulse width >2 μs. Pulse width range is determined by the frequency of the signal.

Input Characteristics

Function

Overload

Protection

Input

Impedance

(nominal)

Common Mode

Rejection Ratio

(1 kΩ unbalance)  

Normal Mode Rejection        

     V

1000V rms

10MΩ<100pF

> 120 dB at dc, 
50 Hz or 60 Hz

> 60 dB at 50 Hz or 60 Hz

  mV

1000V rms

> 120 dB at dc,

50 Hz or 60 Hz

> 60 dB at 50 Hz or 60 Hz

     V

1000V rms

   10MΩ<100pF

  (ac-coupled)

> 60 dB, dc to 60 Hz

Open Circuit

Test Voltage

Full Scale Voltage

Typical Short Circuit Current

To 6   MΩ

5MΩ  or

    60 nS

1kΩ

10kΩ

100kΩ

1MΩ

10MΩ

50MΩ

W

1000V rms

<2.8 V dc

 <850mV dc

 <1.3V dc

500μA

100μA

10μA

1μA

0.2μA

0.1μA

 -

1000V rms

<2.8 V dc 

2.200 V dc

1.0 mA typical

Power Source :006P DC9V

Weight/Size :  Approx. 370g / 186mm(L)×84mm(W)×51mm(T), (7.32"L×3.31"W×2.0"T)

Accessories :  Test leads (pair), Battery, Operating Instruction.

 

 

 