PROVA-8500 Energy-Saving Tester
|
|
|
1. Specifications of Front Panel (AC Sine Wave Output)
|
Range |
Resolution |
Accuracy |
Comment |
85V - 250V |
0.1V |
±1% |
THD < 2% |
45Hz - 65Hz
|
0.01Hz |
± 0.1 Hz |
- |
10mW - 100W
|
0.1mW |
± 1 % ± 0.05W |
- |
5mA – 0.6A |
0.1mA/ 1mA |
± 1 % ± 0.5mA |
(Remark 1) |
0.6A – 1.5A |
± 1 % ± 5mA |
PF (0 ~ 1) |
0.001PF |
±0.1Hz |
- |
|
Remark 1:The max. output power is around 100W, so the output current may be varied according to the voltage setup value. For example, after setting up the voltage which is ≧ 150V, the max. output current will be 0.75A only.
|
|
|
2. Specifications of Rear Panel (Max. 2000W, AC Measurement)
|
Range |
Resolution |
Accuracy |
100mW - 2000W |
0.1mW/1mW/ 0.01W/0.1W/1W
|
± 1 % ± 0.5W |
85V - 250V |
0.1V |
± 1 % |
5mA – 0.6A |
0.1mA/ 1mA/ 0.01A
|
± 1 % ± 5mA |
0.6A – 1.5A |
± 1 % ± 50mA |
1.5A - 10A |
± 1 % ± 0.1A |
PF (0~1) |
0.001PF |
± 0.04 |
45Hz - 65Hz |
0.01Hz |
± 0.1Hz |
THD (0.0 - 20.0%) |
0.1% |
± 2% |
THD (20.0 – 100%) |
±3% of reading ±5% |
THD (1000 – 999.9%) |
±10% of reading ±10% |
Hn (1 – 10th) |
0.1mA/ 0.001A/ 0.01A\
|
reading in mA: ±1.4% of reading ±1mA reading in A: ±1.4% of reading ±0.1A |
Hn (11 – 20th) |
reading in mA: ±4% of reading ±1mA reading in A: ±4% of reading ±0.1A |
Hn (21 – 50th, A range) |
reading in mA: ±10% of reading ±1mA reading in A: ±10% of reading ±0.1A |
Hn (21 –50th, mA range) |
reading in mA: ±20% of reading ±1mA reading in A: ±20% of reading ±0.1A |
|
|
3. Input Power Source:110V (90V - 130V) / 220V (200V - 240V), 45Hz - 65Hz, MAX 10A
4. Power Fuse:250V 10A。
5. Operation Humidity:< 80%RH。
6. Operation Temperature:4°C - 60°C
7. Accessories:Power cord x 1, Users manual x 1, Software CD x 1, Software users manual x 1,RS-232Cto USB bridge x 1
8. Dimensions:260mm x 151mm x 305mm (10.2" x 5.9" x 12")
9. Weight:9.9 kg / 21.8 lb
|
|