TES-3063/3064 Power AC/DC Clamp Meter
|
|
1 Φ 2W, 1 Φ 3W,3 Φ 3W,3 Φ 4W
- RS-232 interface to talk with PC
- 4 digits with dual display LCD
- Amp / Voltage f requency measurement
- Dual display KW+PF , KVA+PF , V+A
- 4000 continuity point data logger , 25 point manual data logger
- True power / apparent power / power factor measurement
- True RMS. V , A , W , cap , lnd , phase indicator
- MIN / MAX measurement
- Peak hold detector
- Dual display A+Hz , V+Hz
EN61010-1 600V Installation CAT III Pollution Degree 2 |
True Power & Apparent power measurement |
Input
|
Resolution
|
Accuracy
|
Frequency range
|
Overload protection
|
V<130V, A<150A
|
0.01
|
+/- (2%+5)
|
45Hz - 500Hz
|
600V/1100A
|
V>130V, A<150A
|
V<130V, A>150A
|
V>130V, A>150A
|
0.1
|
+/- (2%+1)
|
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
1000A
|
0.1A
|
+/- (1.5%rdg + 5dgts)
|
1100A
|
|
Range
|
Resolution
|
Accuracy
|
Frequency range
|
Overload protection
|
1000A
|
0.1A
|
+/- (1.5%rdg + 5dgts)
|
45Hz - 500Hz
|
1100A
|
‧Crest Factor: <4 for stated accuracy |
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload protection
|
600V
|
0.1V
|
+/- (0.5%rdg + 5dgts)
|
1M Ω
|
600V
|
|
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Frequency range
|
Overload rotection
|
600V
|
0.1V
|
+/- (0.5%rdg + 5dgts)
|
1M Ω
|
45Hz - 500Hz
|
600Vms
|
‧Crest Factor: <3 for stated accuracy |
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
20A - 80A
|
0.1A
|
+/- (10%rdg + 10dgts)
|
1100A
|
80A - 1000A
|
+/- (6%rdg + 10dgts)
|
‧Peak Detect Acquisitions Time<=1ms |
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
20V - 80V
|
0.1V
|
+/- (10%rdg + 10dgts)
|
600Vrms
|
80V - 600V
|
+/- (6%rdg + 10dgts)
|
‧Peak Detect Acquisitions Time<=1ms |
|
Range
|
Continuity beeper
|
Open circuit voltage
|
Overload protection
|
|
<=0.050
|
<=3.2V
|
600Vrms
|
|
Range
|
Resolution
|
Accuracy
|
Frequency range
|
Overload protection
|
10K Ω
|
1 Ω
|
+/- (1%rdg + 5dgts)
|
<=3.2V
|
600Vrms
|
|
Range
|
Resolution
|
Overload protection
|
|
0.001V
|
600Vrms
|
|
Range
|
Resolution
|
Accuracy
|
Voltage sensitivity
|
Overload protection
|
1KHz
|
0.1Hz
|
+/- (0.5%rdg + 5dgts)
|
10V or 10A
|
600V / 1100A
|
5KHz
|
1Hz
|
|
Optional Accessories: TES-3064 RS-232 Interface Adaptor / Software |
|
Maximum Voltage between any terminal and earth ground |
600Vrms |
Numerical Dual Display |
4 digit liquid crystal display (LCD) maximum reding 9999. |
Bargraph display |
40 Segments. |
Battery Life |
30hr approx. (Alkaline) |
Jaw Opening Diameter |
Cables f 46mm. |
Operating Temperature and Humidity |
0 ℃to 50 ℃ (32 ℉ to 122 ℉ ) R.H. < 80% non-condensing. |
Storage Temperature and Humidity |
-10 ℃ to 60 ℃ (14 ℉ to 140 ℉ ) R.H. < 70% non-condensing. |
Dimensions |
260mm(L) x 93mm(W) x 45mm(H) |
Weight |
Approx. 450g |
Accessories |
Carrying Case, Test leads, One 9V Battery & Instruction manual |
|